11 vrst dihalnega patogena

Kratek opis:

This kit is used for the in vitro qualitative detection of common clinical respiratory pathogens in human sputum, including Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumoniae (KPN), Stenotrophomonas Maltofilija (SMET), Bordetella Ortussis (BP), Bacillus parapertuss (BPP), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (CPN), Legionella pneumophila (nog). Rezultate lahko uporabimo kot pomoč pri diagnozi hospitaliziranih ali kritično bolnih bolnikov z domnevnimi bakterijskimi okužbami dihal.This kit is used for the in vitro qualitative detection of common clinical respiratory pathogens in human sputum, including Haemophilus influenzae (HI), Streptococcus pneumoniae (SP), Acinetobacter baumannii (ABA), Pseudomonas aeruginosa (PA), Klebsiella Pneumoniae (KPN), Stenotrophomonas Maltofilija (SMET), Bordetella Ortussis (BP), Bacillus parapertuss (BPP), Mycoplasma pneumoniae (MP), Chlamydia pneumoniae (CPN), Legionella pneumophila (nog). Rezultate lahko uporabimo kot pomoč pri diagnozi hospitaliziranih ali kritično bolnih bolnikov z domnevnimi bakterijskimi okužbami dihal.


Podrobnosti o izdelku

Oznake izdelkov

Ime izdelka

HWTS-RT162A 11 Vrste dihalnega patogena nukleinske kisline komplet(Fluorescenca PCR)

Kanal

靶标 Kanal
核酸反应液 a 核酸反应液 b 核酸反应液 c 核酸反应液 d
HI SMET MP Noga Fam
SP PA Bp / Cy5
Kpn Aba Bpp Cpn Rox
内参 内参 内参 内参 Vic/Hex

Epidemiologija

Okužbe dihalnih traktov so pomemben razred bolezni, ki resno ogrožajo zdravje ljudi, in študije so pokazale, da večino okužb z dihali povzročajo bakterijski in ali virusni patogeni, ki sobivajo gostitelja, kar vodi do povečane resnosti bolezni in celo smrt, zato razjasnitev patogena omogoča ciljno zdravljenje in izboljša stopnjo preživetja pacienta[1,2].

Tehnični parametri

Skladiščenje

≤-18 ℃

Rok trajanja 12 mesecev
Vrsta vzorca Sputum
Ct Živjo 、 sp 、 kpn 、 pa 、 aba 、 smet : ct≤33BP 、 BPP 、 MP 、 CPN 、 noga: CT≤38
CV <5,0%
Lod Klebsiella pneumoniae, Streptococcus pneumoniae, Haemophilus influenzae, pseudomonasaeruginosa, acinetobacter baumannii, stenotrophomonas maltophilia in legionellaPneumophila: 1000 CFU/ml

Bordetella pertussis in bacillus parapertussis: 500 CFU/ml;

Mycoplasma pneumoniae in chlamydia pneumoniae: 200 kopij/ml.

Specifičnost Rezultati testov navzkrižne reaktivnosti so pokazali, da med tem kompletom in citomegalovirusom ni bilo navzkrižne reakcije, virus herpes simpleksa tipa 1, virus norice-zoster, virus Epstein-Barr, Bordetella Pertussis, Corynebacterium, Escherichia coli, LEGIOPHILUS influenzae, LactAcIllae, LactAcIllae, LactAcIllae, LactAcIllae, LactACillae, LactAcIllae, LactACillae, LactACillae, LactACillae, LactACillae, LactACILLAE, LACTOPHILLAE, LACTOPHILUS, LACTOPHILUS, LACTOPHILLAE, LACTOPHILAES , Moraxella Catarrhalis, attenuated strains of Mycobacterium tuberculosis, Neisseria meningitidis, Neisseria, Pseudomonas aeruginosa, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pyogenes, Streptococcus salivarius, Acinetobacter baumannii, Stenotrophomonas maltophilia, Burkholderia cepacia, Corynebacterium striatum, Nocardia, Serratia marcescens, Citrobacter, Cryptococcus, Aspergillus fumigatus, Aspergillus flavus, Pneumocystis jiroveci, Candida albicans, Rothia mucilaginosus, Streptococcus oralis, Klebsiella Pneumoniae, Chlamydia Psittaci, Coxiella Burntii in človeške genomske nukleinske kisline.
Veljavni instrumenti Applied Biosystems 7500 PCR sistemi v realnem času

Applied Biosystems 7500 Hitri PCR sistemi v realnem času

QuantStudio®5 sistemov PCR v realnem času

PCR sistemi PCR v realnem času SLAN-96P

Lightcycler®480 PCR sistem v realnem času

Linegene 9600 plus sistemi za zaznavanje PCR v realnem času

MA-6000 Kvantitativni toplotni kolesar v realnem času

Biorad CFX96 PCR sistem v realnem času

Biorad CFX OPUS 96 PCR sistem v realnem času

Delovni tok

Makro in mikro test Splošni komplet DNA/RNA (HWTS-3019) (ki ga je mogoče uporabiti z makro in mikro-test samodejnim ekstraktorjem nukleinske kisline (HWTS-3006C, HWTS-3006B)) Jiangsu Macro & Micro-Tech Med-Tech Co., Ltd. Dodajte 200 µlfiziološkofiziološko raztopino za predelano oborino in naslednje korake je treba izvesti v skladu z navodili. Priporočeni volumen elucije je 100 ul.


  • Prejšnji:
  • Naslednji:

  • Tu napišite svoje sporočilo in nam ga pošljite